Acoustic enclosures for heat pumps, chillers and commercial refrigeration

Matching enclosures for the best-selling large units – free for design work: enclosure dimensions, noise reduction, weight and budget price per unit, specification texts and your selection as a PDF. No sign-up required. Other manufacturers via manual entry.

Made to fit each unitDesign standard: 800 mm at the sides, 900 mm above the unit for upward discharge, 100 mm for side discharge. Enclosures without floor, contact-free around the unit.
InstallationOn a foundation with anti-vibration mounts (+120 mm) or on a steel frame of any height. Base, mounts and frame by others – the enclosure height is adapted.
Tube silencerABSORA HSA3 tubes Ø 200 mm in the discharge, HSA3 inner lining (A1), MiniTec 45 × 45 frame. Manufacturer missing?
Acoustic enclosures for large heat pumps in a residential setting – modular aluminium panels with louvre bands for the air flow.
Acoustic enclosures for large heat pumps in a residential setting – modular aluminium panels with louvre bands for the air flow.

Other manufacturers – manual entry

For units not in the catalogue, or if your dimensions differ: enter the datasheet dimensions. The enclosure is designed live and can be added to your enquiry.

Unit

Installation and acoustics

Clearances to enclosure outer edge

Drag to rotate · double-click restarts rotation

Catalogue overview as a table

Acoustic enclosures for heat pumps, chillers and commercial refrigeration – all units

Enclosure dimensions and prices for one unit on a foundation with anti-vibration mounts (120 mm). Steel frame installation and 2 or 3 units under one enclosure are available; other manufacturers via manual entry. All budget prices net, excl. installation, VAT and freight. Binding quotation after review. As of October 2026.

ManufacturerSeriesMatching modelsUnit (L × W × H)Enclosure (L × W × H)Standard approx. −15 dB(A)Premium approx. −20 dB(A)Item no.
DaikinEWYT-CZ (R32, Inverter)EWYT021CZO1,152 × 802 × 1,878 mm2.75 × 2.40 × 3.50 m€17,700€21,050FCT-GA-DK-CZ1-F
DaikinEWYT-CZ (R32, Inverter)EWYT032CZO, EWYT040CZO1,752 × 802 × 1,878 mm3.35 × 2.40 × 3.50 m€20,350€24,350FCT-GA-DK-CZ2-F
DaikinEWYT-CZ (R32, Inverter)EWYT064CZO2,906 × 814 × 1,878 mm4.51 × 2.41 × 3.50 m€26,150€31,600FCT-GA-DK-CZ3-F
DaikinEWYT-B (R32)EWYT085B2,225 × 1,195 × 1,800 mm3.83 × 2.80 × 3.42 m€25,000€30,300FCT-GA-DK-B1-F
DaikinEWYT-B (R32)EWYT135B, EWYT175B3,425 × 1,195 × 1,800 mm5.03 × 2.80 × 3.42 m€30,600€37,600FCT-GA-DK-B2-F
DaikinEWYT-B (R32)EWYT235B, EWYT255B4,950 × 1,195 × 1,800 mm6.55 × 2.80 × 3.42 m€37,750€46,900FCT-GA-DK-B3-F
DaikinEWYT-B (R32)EWYT390B, EWYT490B, EWYT540B4,125 × 2,282 × 2,514 mm5.73 × 3.88 × 4.13 m€46,950€58,050FCT-GA-DK-B4-F
HiRefTPL (Luft/Wasser-WP)30TPL4863,300 × 1,200 × 2,000 mm4.90 × 2.80 × 3.62 m€31,150€38,000FCT-GA-HR-TPL1-F
HiRefTPL (Luft/Wasser-WP)30TPL818HQ04,500 × 2,200 × 2,400 mm6.10 × 3.80 × 4.02 m€47,800€59,350FCT-GA-HR-TPL2-F
HiRefNHA (R290)30NHA604HL03,000 × 1,200 × 1,900 mm4.60 × 2.80 × 3.52 m€29,150€35,600FCT-GA-HR-NHA-F
ThermocoldDOMINO HP N (R290)DOMINO HP N 018 XLN2,085 × 1,100 × 2,328 mm3.69 × 2.70 × 3.95 m€26,200€31,200FCT-GA-TC-DOM-F
WeishauptWWP LA (R290, bis 60 kW)WWP LA (kleine Baugröße)1,740 × 880 × 1,520 mm3.83 × 2.48 × 1.74 m€12,100€14,250FCT-GA-WH-LA-F
ViessmannVitocal 250-A PRO (R290)AWO-AC-AF 251.A401,900 × 940 × 1,570 mm4.01 × 2.54 × 1.79 m€12,800€15,050FCT-GA-VI-250-F
Bosch / BuderusCompress 7400i AW / Logatherm WLW186i ARCS7400iAW 17 O, WLW186i-14 AR930 × 440 × 1,380 mm2.98 × 2.04 × 1.60 m€9,050€10,700FCT-GA-BB-7400-F
VaillantaroTHERM plus (R290)VWL 35/6 A, VWL 55/6 A1,100 × 450 × 765 mm2.97 × 2.05 × 0.99 m€6,000€7,000FCT-GA-VA-ATP1-F
VaillantaroTHERM plus (R290)VWL 105/6 A, VWL 125/6 A1,100 × 450 × 1,565 mm3.21 × 2.05 × 1.79 m€10,250€12,100FCT-GA-VA-ATP2-F
Mitsubishi ElectricEcodan CAHV-R450 (R454C)CAHV-R450YA-HPB1,750 × 740 × 1,710 mm3.35 × 2.34 × 3.33 m€19,300€23,250FCT-GA-ME-CAHV-F
Mitsubishi Electric / Climavenetai-FX-N (Schraube, Inverter)i-FX-N 4724,900 × 2,260 × 2,580 mm6.50 × 3.86 × 4.20 m€52,050€64,600FCT-GA-CV-IFX1-F
Mitsubishi Electric / Climavenetai-FX-N (Schraube, Inverter)i-FX-N 7727,900 × 2,260 × 2,580 mm9.50 × 3.86 × 4.20 m€71,550€89,850FCT-GA-CV-IFX2-F
NIBEF2120F2120-81,130 × 610 × 1,070 mm3.09 × 2.21 × 1.29 m€8,000€9,400FCT-GA-NI-2120a-F
NIBEF2120F2120-12, F2120-16, F2120-201,280 × 612 × 1,165 mm3.27 × 2.21 × 1.39 m€8,700€10,200FCT-GA-NI-2120b-F
Stiebel EltronWPL 47 / 57 AWPL 47 A, WPL 57 A1,930 × 1,100 × 1,500 mm4.02 × 2.70 × 1.72 m€12,800€15,150FCT-GA-SE-WPL-F
PanasonicAquarea T-CAP (3-phasig)WH-MXC16J9E81,283 × 320 × 1,410 mm3.34 × 1.92 × 1.63 m€9,300€10,850FCT-GA-PA-TCAP-F
AermecNRK (Hochtemperatur-WP)NRK 0200 E, NRK 0280 E2,700 × 1,100 × 1,606 mm4.30 × 2.70 × 3.23 m€25,650€31,450FCT-GA-AE-NRK1-F
AermecNRK (Hochtemperatur-WP)NRK 0350 A, NRK 0500 A, NRK 0600 A3,330 × 1,100 × 1,875 mm4.93 × 2.70 × 3.50 m€29,950€36,600FCT-GA-AE-NRK2-F
AermecNRK (Hochtemperatur-WP)NRK 0650 A, NRK 0700 A4,330 × 1,100 × 1,875 mm5.93 × 2.70 × 3.50 m€34,600€42,600FCT-GA-AE-NRK3-F
SwegonBlueBox ZETA Sky (R32)ZETA Sky 3.22,200 × 1,000 × 1,799 mm3.80 × 2.60 × 3.42 m€23,750€28,700FCT-GA-SW-ZS1-F
SwegonBlueBox ZETA Sky (R32)ZETA Sky 9.23,200 × 1,100 × 2,380 mm4.80 × 2.70 × 4.00 m€32,050€38,550FCT-GA-SW-ZS2-F
SwegonBlueBox ZETA Sky (R32)ZETA Sky 13.2, ZETA Sky 18.4, ZETA Sky 24.44,200 × 1,100 × 2,380 mm5.80 × 2.70 × 4.00 m€37,050€44,900FCT-GA-SW-ZS3-F
YORK / Johnson ControlsYMAE (Inverter-Scroll, modular)YMAE02602,160 × 1,130 × 2,370 mm3.76 × 2.73 × 3.99 m€26,950€32,100FCT-GA-YK-YMAE-F
TraneSintesis CGAF / CXAFCGAF 060, CXAF 0603,395 × 2,200 × 2,350 mm5.00 × 3.80 × 3.97 m€40,750€50,250FCT-GA-TR-CXAF1-F
TraneSintesis CGAF / CXAFCXAF 150 SE XLN5,645 × 2,200 × 2,530 mm7.25 × 3.80 × 4.15 m€56,450€70,200FCT-GA-TR-CXAF2-F
ENGIE RefrigerationQUANTUM Air / Wärmepumpen 250 kW – 2 MWQUANTUM AirThis series is built per project in many sizes – there is no standard enclosure for it. Please enter dimensions and sound data from the datasheet in the manual entry.
DaikinEWAT-B (R32)EWAT085B2,120 × 1,204 × 1,801 mm3.72 × 2.80 × 3.42 m€24,550€29,750FCT-GA-DK-EW1-F
DaikinEWAT-B (R32)EWAT155B3,570 × 1,204 × 1,822 mm5.17 × 2.80 × 3.44 m€31,450€38,700FCT-GA-DK-EW2-F
DaikinEWAT-B (R32)EWAT195B4,170 × 1,204 × 1,822 mm5.77 × 2.80 × 3.44 m€34,300€42,400FCT-GA-DK-EW3-F
DaikinEWAT-B (R32)EWAT240B2,326 × 2,236 × 2,540 mm3.93 × 3.84 × 4.16 m€35,600€43,100FCT-GA-DK-EW4-F
DaikinEWAT-B (R32)EWAT310B3,226 × 2,236 × 2,540 mm4.83 × 3.84 × 4.16 m€41,150€50,450FCT-GA-DK-EW5-F
CarrierAquaSnap 30RB30RB 060, 30RB 070, 30RB 0802,413 × 2,235 × 2,286 mm4.01 × 3.84 × 3.91 m€34,700€42,400FCT-GA-CA-30RB1-F
CarrierAquaSnap 30RB30RB 120, 30RB 130, 30RB 1504,801 × 2,235 × 2,286 mm6.40 × 3.84 × 3.91 m€49,050€61,350FCT-GA-CA-30RB2-F
Carrier61AQ Wärmepumpe (R290, 40–130 kW)61AQThis series is built per project in many sizes – there is no standard enclosure for it. Please enter dimensions and sound data from the datasheet in the manual entry.
MideaModular-Chiller King PlusMC-SS130-RN1TL2,300 × 1,120 × 2,200 mm3.90 × 2.72 × 3.82 m€26,800€32,100FCT-GA-MI-KP-F
LGLuftgekühlte KaltwassersätzeScroll / Inverter-ChillerThis series is built per project in many sizes – there is no standard enclosure for it. Please enter dimensions and sound data from the datasheet in the manual entry.
Dunham-BushLuftgekühlte Schrauben-ChillerACDX / ACDSThis series is built per project in many sizes – there is no standard enclosure for it. Please enter dimensions and sound data from the datasheet in the manual entry.
SmardtÖlfreie Turbocor-Chiller (luftgekühlt)AeroPure / AJThis series is built per project in many sizes – there is no standard enclosure for it. Please enter dimensions and sound data from the datasheet in the manual entry.
GreeModular-Chiller / WärmepumpenLSQWRFThis series is built per project in many sizes – there is no standard enclosure for it. Please enter dimensions and sound data from the datasheet in the manual entry.
PanasonicCO₂-Verflüssigungssatz iCORE OCU-CROCU-CR1000VF8890 × 890 × 1,941 mm3.09 × 2.49 × 2.16 m€13,550€16,250FCT-GA-PA-OCU-F
DaikinConveni-Pack / ZEAS (Verflüssigungssatz)LRYEN10A7Y1, LREN8A7Y11,240 × 765 × 1,680 mm2.84 × 2.37 × 3.30 m€17,200€20,550FCT-GA-DK-CVP-F
CarrierCO₂OLtec Verbundanlagen / VerflüssigungssätzeCO₂OLtecThis series is built per project in many sizes – there is no standard enclosure for it. Please enter dimensions and sound data from the datasheet in the manual entry.
HillphoenixAdvansor CO₂-VerbundanlagenAdvansorThis series is built per project in many sizes – there is no standard enclosure for it. Please enter dimensions and sound data from the datasheet in the manual entry.
LiebherrGewerbekühl- und TiefkühlgeräteSteckerfertigPlug-in refrigeration cabinets have no outdoor unit and need no acoustic enclosure. For condensing units, dry coolers or rack systems please use the manual entry.
HoshizakiEisbereiter, Kühl- und TiefkühlschränkeSteckerfertigPlug-in refrigeration cabinets have no outdoor unit and need no acoustic enclosure. For condensing units, dry coolers or rack systems please use the manual entry.
HaierGewerbekühlungSteckerfertigPlug-in refrigeration cabinets have no outdoor unit and need no acoustic enclosure. For condensing units, dry coolers or rack systems please use the manual entry.

About ForCoTech: ForCoTech is the acoustic enclosure brand of Silent Engineering di Romolo Vicari (Osnago, Italy), built with Absora technology. Enclosures are engineered per project – acoustics, pressure drop and structural design, including CFD simulation – for heat pumps, chillers, dry coolers, VRF/VRV outdoor units and PV inverters. More about us: www.forcotech.com · Contact: info@forcotech.com · silent-mode.com

Example quotation for this category: B-01 Large heat pump with roof splitter package (PDF, German) · B-03 Heat pump with tube silencer – 2 variants (PDF, German) · all example quotations →