
Quiet for the neighbours.Performance for the unit.Acoustic enclosures for heat pumps and HVAC systems
Proof first, then the enclosure. For heat pumps, chillers, VRF, PV inverters and BESS we calculate the level at the receiver in advance and design acoustics and airflow together – built with Absora technology.
- Proof before you order: level at the receiver point calculated in advance (TA Lärm)
- Max. 3–5 % performance loss: airflow engineered with CFD
- Patented HSA3 technology: A1 non-combustible, also for R290 – tested in a reverberation room
Preliminary sizing instantly in the configurator · list prices for standard enclosures · binding quotation for complex projects usually within 2–3 days
Who is behind ForCoTech
- 1EngineeringSilent Engineering, Osnago (IT)Acoustics, airflow (CFD) and structural design – your contact for quotation and project
- 2Manufacturing & installationtogether with ABSORA GmbH, BerlinDeveloper and patent holder of the HSA3 acoustic meta-metal
- 3Your enclosuredelivered and installed on requestunder the ForCoTech and Silent-Mode brands

Romolo Vicari, founder. While developing heat pumps in China, he saw that outdoor-unit noise can become the biggest obstacle – so he developed the matching acoustic enclosures himself. First projects in the UK in 2015, more than 500 installations since. More about us →
Hear the difference
Original recordings alternating every 3 seconds: first without, then with the enclosure – headphones recommended.
Recording at an inverter enclosure
Recording at a machine enclosure
Recordings: ABSORA GmbH. The loudness of a recording is not a measured value; what counts is the level calculation or measurement at the receiver point.
Proof first, then the enclosure
This is how every ForCoTech enclosure is created – from a single enclosure to a complete plant room. You are not buying insulation by rule of thumb, but a calculated result.
- Data
Capture the unit and pre-size
Enter unit, dimensions and acoustics in the online configurator – outer dimensions, noise reduction, pressure drop and wind load instantly, list price for standard enclosures. For consultants with design sheet, tender text and BIM model (IFC).
Open configurator → - Proof
Calculate the level at the receiver
We calculate the level at the relevant receiver in advance (TA Lärm). You know before ordering whether the limits will be met – typically −15 to −20 dB(A), more on a project basis.
Engineering → - Design
Acoustics, airflow and structure together
Airflow designed with CFD, HSA3 lining with up to 40 % less pressure drop than conventional splitters – max. 3–5 % loss of performance. A1 non-combustible, for R290 with protection zone and gas detection.
Airflow and R290 → - Delivery
Quotation, manufacturing, measurement
Binding quotation with drawing, usually within 2–3 days. Manufactured with ABSORA, delivered and installed on request; custom builds in 40–60 days. On request we measure before and after installation.
Start your project →

Mass-spring principle with resonance cavity
The perforated acoustic meta-metal oscillates over a resonance cavity and converts sound energy into motion. The result: high attenuation with a smooth, open surface – A1 non-combustible and up to 40 % less pressure drop than conventional splitters.
Measured on a project in Berlin-Adlershof →HSA3 in detail →

What we need to know
- Air flow (m³/h) or cooling / heating capacity (kW)
- Manufacturer and model number of the unit
- Distance to the nearest receiver and the noise limit that applies there
- Installation on a flat roof (weight limit) or on a ground slab
- Existing noise measurement, installation drawings, site survey or CAD data of the unit
One method – for every installation
From a single heat pump to a plant room with several large heat pumps: every solution follows the same method – designed for the unit, the site and the required noise limit.

Heat pumps and large heat pumps
From compact, split and pool heat pumps (H series) to cascades of several large units in one shared enclosure (CM series), including R290 (propane) – safety zone and gas detection included.
Heat pumps in residential buildings →Large heat pumps and cascades →

Chillers and dry coolers
Enclosures for chillers, top-mounted silencers for the fans of dry coolers and condensers – with verified air flow.
View solution →Large equipment catalogue →

VRF/VRV outdoor units
For horizontal and vertical air discharge. Standard enclosures for Daikin, Mitsubishi Electric, Panasonic, LG, Samsung, Toshiba and Haier, also as module combinations.
from approx. €15,500 net
View solution →VRF/VRV catalogue →

PV inverters and BESS
Designed for the typical noise peaks at 16–18 kHz. Also protects against sun and heat (derating), rain, hail and dust. Wall-mounted or free-standing for 1 to 5 inverters – including Huawei, SMA, Fronius, Sungrow.
from approx. €4,400 net
View solution →PV inverter catalogue →
Battery storage catalogue →
More solutions
Noise barriers and mounting platforms
Where a full enclosure is not possible. The reduction is lower than with an enclosure – but 6 to 10 dB(A) is often enough to meet the limits.
View solution →Configure a noise barrier →
Data centres
Free-standing acoustic packs for chillers and dry coolers on the roof: Helmholtz tube silencers above the fans, A1 non-combustible, pressure drop within the unit reserve.
Data centre solutions →Adiabatic pre-cooling
Noise control that also cools: the adiabatic module in the enclosure pre-cools chiller intake air by approx. 6–9 K on hot days – fewer high-pressure trips, quieter operation. Pilot users wanted.
Adiabatic module →Noise barrier + exhaust silencer
When a barrier alone is not enough and an enclosure does not fit: barrier against side radiation, tubular silencer on the unit against the exhaust path – open at the top, approx. 4–8 Pa.
To the combination →IoT monitoring via LoRaWAN
Wireless sensors for pressure drop, air velocity, temperature, sound level, power consumption (load profile) and refrigerant (infrared, NDIR) – retrofittable, up to ATEX design for R290 units.
IoT services →Design examples
Colour, size and layout depend on the unit and the surroundings – from a compact single enclosure to a large walk-on rooftop enclosure.
When you play a video, it is loaded from YouTube and data is transmitted to Google. See our privacy policy.















Photos from completed projects – without customer names or locations.
Currently in progress

About us
ForCoTech and Silent-Mode were founded by Romolo Vicari. While developing heat pumps in China he realised that the noise of outdoor units can become the biggest obstacle – so he developed the enclosures himself.
The first projects were completed in the United Kingdom in 2015. Since then enclosures have been installed all over Europe, and in smaller numbers in the USA and as far as Australia. Since 2024 Silent Engineering di Romolo Vicari, based in Osnago (Italy), continues the development.
Our design work relies on digital tools – AI, BIM and CFD. Manufacturing is carried out in alliance with ABSORA GmbH, Berlin.
FAQ
Which equipment do you build enclosures for?
For air-to-water and large heat pumps, chillers, dry coolers, VRF/VRV outdoor units, PV inverters and battery storage (BESS), also for data centres – single enclosures or one shared enclosure for several units in cascade.
How much noise reduction is possible?
The Standard version achieves approx. −15 dB(A), the Premium version approx. −20 dB(A). For each project the enclosure is designed to meet the noise limits at the relevant receiver point.
What does an enclosure cost?
Standard enclosures for PV inverters start at approx. €4,400 net, standard enclosures for VRF/VRV outdoor units at approx. €15,500 net (excl. installation, VAT and freight). For the H-Series and the best-selling large units, the catalogue pages in the configurator show fixed list prices. All other enclosures are engineered per project – you receive the price with the quotation, for complex projects usually within 2–3 days.
Does it work with R290 (propane)?
Yes, with written approval from the unit manufacturer and a floorless design that lets leaked propane flow away freely at the bottom. No ignition sources inside the enclosure (except explosion-proof equipment), permanently open ventilation openings; where required, gas detection with explosion-proof forced ventilation.
Does the enclosure reduce efficiency?
Air flow and pressure drop are designed with CFD simulation; air velocity is limited and checked against the fan's available external pressure so the loss of capacity stays at max. 3–5 %. HSA3 has up to 40 % less pressure drop than conventional splitters.
How long do manufacturing and delivery take?
Custom enclosures are usually delivered within 40–60 days from receipt of order. For complex projects you will usually receive the binding quotation within 2–3 days; the delivery date is stated in the quotation.
Why don’t you name reference projects?
Once delivered, the installations belong to our customers. We therefore do not publish customer names or locations without their express consent. Our neutralised sample quotations show what our installations look like.
Start your project
Unit, quantity and location are enough to start – with a data sheet we can check dimensions, air volume and sound power straight away. For complex projects you will usually receive a binding quotation within 2–3 days.
We usually get back to you within 2–3 working days.
- Review of your details – with a short follow-up question if needed
- Level calculation at the receiver and design of acoustics and airflow
- Binding quotation with drawing – usually within 2–3 days for complex projects
Brands ForCoTech and Silent-Mode
Via Trento 22 · 23875 Osnago (LC) · Italy
Email: info@forcotech.com
Web: silent-mode.com
Prefer to size it yourself?





